We built this guide because the top-ranking answers skip the two problems owners actually hit. We read the long, specific owner threads on DIY Solar Forum — the ones with posted meter readings.
Then we cross-checked those numbers against manufacturer spec sheets. The same Generac, Honda and Champion sizing charts feed our wattage database. The physics is friendly. The details are not.
A gas furnace burns gas for heat, so the electrical load is small. The blower motor is almost all of it:
| Component | Running watts | Starting surge |
|---|---|---|
| Blower, older PSC motor (most pre-2015 furnaces) | 350–800 W | up to ~1,900 W |
| Blower, modern ECM motor | 120–450 W | ~700 W, soft-start |
| Hot-surface igniter (brief) | 80–200 W | none |
| Thermostat + control board | 2–5 W | none |
Our database entry for the PSC blower lists 500 W typical with a 1,900 W start — figures from published sizing charts, sanity-checked against owner meter logs.
One owner's Kill A Watt showed 880 W while a clamp meter caught a real peak of 1,560 W. Plug-in meters update about once a second and miss the spike, so trust the surge column, not the cheap meter.
The thread that taught us the most followed a small 1,000 W-class station on a 30-year-old furnace. The igniter lit. The gas fired. The blower never spun. The furnace cycled endlessly — and showed no error code, because the control board saw voltage, just not enough current to start the motor.
Others in the thread confirmed the owner's conclusion. A high-frequency inverter's "2× surge" holds for roughly one 60 Hz cycle — about 16 milliseconds. An old PSC motor can take a full second to spin up.
The sizing rule falls straight out of the owner logs. Give an older furnace at least a 2,000 W-class inverter. Treat the 1,900 W start figure as a one-second demand, not a millisecond blip. ECM furnaces are far gentler — owners run them on 1,000 W-class stations without drama.
Furnaces are hardwired. Three legal ways in, from cheapest to most permanent. An electrician converts the furnace feed to cord-and-receptacle, so you replug it into the battery during an outage. A single-circuit transfer switch guards just the furnace circuit.
A panel interlock lets the battery feed selected circuits. Owners in Michigan posted exactly the first setup — a pre-wired plug they move to the station when the grid drops.
What you never do is the "suicide cord" trick from backfeed videos — a male-to-male cord into a wall outlet. It can energize the utility side and injure a line worker. The forum answer to that question is a wall of warnings for good reason.
Between heat cycles a furnace draws only a few watts for its board. Many stations read that as "nothing is plugged in" and shut their AC output off. The four-day furnace test we cited hit this on night one — the owner's fix was one setting: AC timeout → Never.
Our ECO-mode guide lists where that setting hides for each brand. Change it before the storm.
Heating season math from the logged test: 7.2 kWh ran a 350 W furnace for four days, because the blower cycles — call it 30–50% duty in cold weather.
Your estimate: usable Wh ÷ (blower running watts × duty cycle + 20–50 W inverter standby). Take a 2 kWh station on a 500 W PSC blower at 40% duty, with 30 W standby.
That gives roughly 8–9 hours of heating — a night, not a week. Pick your own numbers with the list-builder, and see the battery-vs-generator math if your outages run to days.
We read 4 full furnace threads for this page and logged one owner's 7.2 kWh, four-day test line by line. We pulled blower figures from 3 published sizing charts into our 106-appliance wattage table. We also verified the starting-watt gap against 2 owner meter readings — 880 W shown, 1,560 W real.
A few control boards refuse a floating-neutral inverter. The symptom owners describe: furnace starts, runs seconds, locks out. The test they run is a neutral-bonding plug in the station's spare outlet — the logged furnace thread tried it both ways. If your board is fussy, have an electrician confirm the bonded setup; it interacts with GFCIs.
Related: sump pump backup compared · LiFePO4 in winter · leave it plugged in?
PSC blowers run 350–800 W and surge to ~1,900 W for up to a second; ECM blowers run 120–450 W and soft-start near 700 W. The battery only powers the blower, igniter and controls — the gas heats.
Inverter "2× surge" ratings hold ~16 milliseconds; an old blower needs up to a second. Owners logged stations that lit the igniter but never spun the blower — with no error code. Size above the one-second inrush.
Electrician-added cord-and-receptacle, a single-circuit transfer switch, or a panel interlock. Never a male-to-male backfeed cord — it can energize the grid side and injure a line worker.
A logged test: 350 W furnace, four days on 7.2 kWh, because blowers cycle at ~30–50% duty. Divide usable Wh by (running watts × duty) plus the inverter's 20–50 W standby.
ECO/low-load timeout. Between cycles the furnace draws a few watts and the station assumes nothing is connected. Set AC timeout to Never — the setting that saved the logged four-day test.
Some control boards reject floating-neutral inverters: start, run seconds, lock out. Owners test a neutral-bonding plug in a spare outlet; have an electrician confirm the final arrangement.